{"title":"Magnetic Flow Meters","description":"\u003cp\u003e \u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--\ntd {border: 1px solid #ccc;}br {mso-data-placement:same-cell;}\n--\u003e\u003c\/style\u003e\n\u003cdiv class=\"term-description\" data-mce-fragment=\"1\"\u003e\n\u003ch2 data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eElectromagnetic Flow Meters: The Ultimate Magmeter\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eThe GTS range of electromagnetic flow meters offers low maintenance, accurate solutions to difficult fluid conditions. Magnetic flow meters, also known as electromagnetic flow meters or mag meters, are popular because they are multidirectional, and enable very precise volumetric flow (sometimes referred to as magnetic flow or mag flow) measurement. Magnetic flow metres are made up of a transmitter and a sensor that work in conjunction to measure flow. It's perfect for wastewater applications, as well as any unclean liquid that's conductive or water-based. Magmeters are also great for applications that demand minimal pressure drop and little maintenance.\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 class=\"view-faq-title\"\u003e\u003cstrong\u003eFrequently Asked Questions About\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003eMagnetic Flow Meters\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cdiv class=\"faq-list\"\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does a \u003cmeta charset=\"utf-8\"\u003e \u003cspan data-mce-fragment=\"1\"\u003emagnetic flow meter \u003c\/span\u003ework?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMagnetic flow meters use a magnetic field to generate and channel liquid flow through a pipe. A voltage signal is created \u003cmeta charset=\"utf-8\"\u003e\u003cspan data-mce-fragment=\"1\"\u003ewhen a conductive liquid or \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003emagnetic flow\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e moves through the flow meter’s magnetic field. The faster the \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003emagnetic flow\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e, the greater the voltage signal generated.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What are the advantages and disadvantages of an electromagnetic flow meter?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cu\u003eAdvantages\u003c\/u\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNo moving parts make it easy to maintain and longer-lasting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan data-mce-fragment=\"1\"\u003eMagmeters\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e are highly accurate with a range of ±0.2% of reading ±1 mm\/s \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eThey do not obstruct flow, making them suitable to measure many different types of fluids.\u003c\/li\u003e\n\u003cli\u003eThey measure the volume flow rate of the fluid under test and are minimally affected by the influence of temperature, pressure, density and viscosity of the fluid.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cu\u003eDisadvantages\u003c\/u\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe measured fluid media must be able to conduct electricity. Non-conductive fluids such as oil and other petroleum-based fluids, cannot be measured.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the minimum conductivity required for a medium?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMagnetic flow meters are best suited for bidirectional flow measures of fluids with a minimum conductivity of \u003cstrong\u003e5 μS\/cm\u003c\/strong\u003e (microS\/cm).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: \u003cspan\u003eHow often should I maintain a magnetic flow meter\u003c\/span\u003e?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYou should maintain your magnetic flow meter regularly by checking the electrode condition and cleaning them regularly to ensure good conductivity. \u003cbr\u003e\u003c\/p\u003e\n\u003ca class=\"close-faq\"\u003eClose FAQs\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","products":[{"product_id":"modmag-electromagnetic-flowmeter","title":"ModMAG® Electromagnetic Flowmeter","description":"\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0567\/3382\/7239\/files\/IND_FB_Enquiry_02_0416.pdf?v=1740619338\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0200\/7466\/files\/flex-solid-paper-clip.svg\" width=\"20\" alt=\"paper-clip\"\u003e\u003cspan style=\"text-decoration: underline; color: rgb(43, 0, 255);\"\u003eFlowmeter Questionnaire\u003c\/span\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0567\/3382\/7239\/files\/ModMAG_M-Series_M1000_Product_Data_Sheet.pdf?v=1642142833\" target=\"_blank\"\u003eM1000 Datasheet\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0567\/3382\/7239\/files\/ModMAG_M2000_Product_Data_Sheet.pdf?v=1642142592\" target=\"_blank\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eM2000 Datasheet\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0567\/3382\/7239\/files\/M-Series_M3000_Electromagnetic_Flow_Meter_Product_Data_Sheet.pdf?v=1642142833\" target=\"_blank\"\u003e\u003cspan\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eM3000 Datasheet\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0567\/3382\/7239\/files\/M-Series_M4000_Product_Data_Sheet.pdf?v=1642142834\" target=\"_blank\"\u003e\u003cspan\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eM4000 Datasheet\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0567\/3382\/7239\/files\/ModMAG_M5000_Product_Data_Sheet.pdf?v=1642142833\" target=\"_blank\"\u003e\u003cspan\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eM5000 Datasheet\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eThe Badger Meter ModMAG range of electromagnetic flowmeters are easy-to-maintain and long-lasting and offer a range of options to suit any flow metering system. They offer high-accuracy and low maintenance, allowing you to meet the challenges of difficult fluid conditions.\u003c\/p\u003e\n\u003cp\u003eContact the \u003ca href=\"\/pages\/contact-us\/\" target=\"_blank\"\u003eGTS Team\u003c\/a\u003e via the contact form, or call our staff on (08) 9250 4400 to learn more.\u003c\/p\u003e\n\u003ch3\u003eFeatures:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNo moving parts in flow stream — easy to maintain with a long-service life\u003c\/li\u003e\n\u003cli\u003eMeasures water, water-based fluids and other liquids\u003c\/li\u003e\n\u003cli\u003eSuitable for a wide range of flow measuring applications\u003c\/li\u003e\n\u003cli\u003eBattery-powered options are available to order — contact GTS today!\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-family: Aptos, sans-serif; color: red; text-decoration: underline;\"\u003eSHIPPING ONLY AVAILABLE WITHIN AUSTRALIA \u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cimg style=\"float: none;\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0567\/3382\/7239\/files\/Authorized_Distributor_Logo_blue_low_res_240x240.png?v=1629418905\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e \u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0567\/3382\/7239\/files\/Modmag_Logo_240x240.jpg?v=1629420712\"\u003e\u003cbr\u003e\n\u003c\/div\u003e","brand":"GTS Gauges","offers":[{"title":"Default Title","offer_id":40047214133415,"sku":"ModMAG","price":0.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0567\/3382\/7239\/products\/M1000_grey_label_blue_96dpi.jpg?v=1759292169"}],"url":"https:\/\/gtsgauges.com.au\/collections\/magnetic-flow-meters\/electromagnetic-flow-meters.oembed","provider":"GTS Gauges","version":"1.0","type":"link"}